F381 |
|
Dynamic Force Processor |
|
|
|
|
|
|
|
- Waveform comparison function(Sequential comparison of HI/LO limit waveform and actual measurement waveform)
- Multi hold function (HI/LO limit comparison is carried out by changing the type of hold function in each divided measurement segments)
- Standard equipped with displacement input(A 2-dimentional waveform comparison is possible by using both force and displacement inputs)
- Measurement data and setting values can be saved into a SD card
- Parameter setting can be effortlessly performed by a direct touch on the touch panel.
- Plus common and minus common are shared, and Sink/Source type is selectable
- 4000 times/sec high-speed digital processing
|
|
|
|
|
|
|
|
|
F395 |
|
Dynamic Force Processor |
|
|
|
|
|
|
|
- After digitizing the signal of a sensor and carrying out filtering and operation processing by high-speed(up to 4000 times/sec) A/D and a D/A converter, it can be used as a signal conditioner outputted as an analog signal by which the scaling was carried out.
- Multi-hold is the mode which detects the required item in the displayed wave and judges upper/lower comparison. It can memorize 32ch data which is hold type, upper/lower value, etc, and it can select with an external signal.
- LCD with touch-panel display excellent in visibility and operativity, such as a measurement value display and a wave display, is adopted.
|
|
|
|
|
|
|
|
|
F372 |
|
Graphic Display Digital Indicator |
|
|
|
|
|
|
|
- Replacement Model of F370/F371 with Expansion functions.
- Expansion functions of the F372:
--Double Hold.
--Before Value Comparison.
--Relative Value Comparison.(In Double Hold only)
--Digital Filter Character selection.
--Trigger Edge selection.
--Pre Trigger display.
- To all persons who use the F370/F371-Smooth replacement can be made because the F372 is compatible with the F370/F371 in terms of setting methods and functions except for the use of the expansion functions.
|
|
|
|
|
|
|
|
|
F377 |
|
Color Graphic Display/Touch Panel Type Digital Indicator for Voltage・Current output Sensor |
|
|
|
|
|
|
|
- Can be connected directly to Voltage ±10V, Current ±20mA.
- The changes in physical quantity are displayed in the waveform.
- Various Hold functions that enable to hold accurate point and the function of OK/NG judgment.
- Two points Hold (previously measured value comparison, relative value comparison etc.) that can perform two types of Hold simultaneously are installed.
- Compact size of DIN96 □
- High-speed digital processing capability of 2000 times/sec.
|
|
|
|
|
|
|
|
|
F370 |
|
Graphic Display Digital Indicator |
|
|
|
|
|
|
|
- Color liquid crystal display and touch operation provide clear indication and easy handling.
- Equivalent Input Calibration makes easy calibration by inputting the Rated Value of a sensor by the touch panel.
- One touch Zero Function.
- Compact Square DIN96 size.
- High speed HIGH/ LOW limit comparison function.
*F370/F371 are being shifted to brand new model, F372 currently.
Please ask our sales department for production termination schedule of F370/F371.
|
|
|
|
|
|
|
|
|
F371 |
|
Graphic Display Digital Indicator |
|
|
|
|
|
|
|
- Advanced model of F370.
- Additional specifications:
- RS-232C Interface installed as a standard option.
- Analog monitor output function (Approx. 2V per 1mV/V imput)e.
- Multi-Calibration function (up to 4 types of calibration values cen be stored/ selected via bexternal signal).
*F370/F371 are being shifted to brand new model, F372 currently.
Please ask our sales department for production termination schedule of F370/F371.
|
|
|
|
|
|
|
|
|
F320 |
|
Digital Indicator |
|
|
|
|
|
|
|
- Mini DIN 96 x 48mm size.
- Standard built-in RS-485 with Modbus-RTU communication protocol.
- 2000times/sec High-speed A/D conversion
- High/ Low Limit Comparison Function with Hysteresis
- Peak/ Sample hold functions
- Digital Zero function.
|
|
|
|
|
|
F350 |
|
2ch Input Type Digital Indicator |
|
|
|
|
|
|
|
- Calculation and judgment outputs can be made with respect to 2ch input values of strain gauge type sensors.
- Calculation functions
(ch1+ch2, ch1−ch2, |ch1−ch2|, High select, Low select)
- 9 points of judgment outputs are equipped.
- 3000 times/sec high-speed digital processing
- Equivalent Input Calibration makes easy calibration by inputting the Rated Value of a sensor by keypad.
|
|
|
|
|
|
|
|
|
F340A |
|
Compact Type Digital Indicator |
|
|
|
|
|
|
|
- Equivalent Input Calibration makes easy calibration by inputting the Rated Value of a sensor by keypad.
- Analog peak hold function provides the ultra-high speed peak hold.
- One touch Zero function.
- Compact Square DIN96 size.
- High speed HIGH/ LOW limit comparison function.
|
|
|
|
|
|
F490 |
|
Portable Digital Indicator with Recording Function |
|
|
|
|
|
|
|
- Suitable for portable use with lightweight design of 380g.
- The measurement data is recorded in CSV form in its internal memory.
- The data recorded can be referred to and copied through USB interface.
- Various display modes such as graphic display, recorded data display and so on
- Multi Calibration function enables to store the calibration value for 4ch and allows the calibration value to select at will as required by the site sensor.
- 4 types of Hold functions such as Sample, Peak, Bottom and Peak to peak Hold can set the observation range.
|
|
|
|
|
|
|
|
|
F130 |
|
LOADCELL INTERFACE FOR OMRON SYSMAC CJ1 |
|
|
|
|
|
|
|
- Direct connection to Omron Sysmac CJ1 network system
- High speed A/D conversion 3000times/sec
- Inter-equipments wiring can be greatly simplified
- Cost effective weighing system is available
- System development time is shortened