F701-S
Product Outline
High grade unit that pursues high specifications and functions.
F701-S is a weighing indicator with high specifications and various functions such as super-low-drift high-precision amplifier, fast-sampling, weighing sequence functions that are useful for automatic weighing machines and control I/O.
Specifications
Analog|Setting|External signal|Interface|Display|General specification|Attachment
| Analog | |
| Excitation voltage | DC5V±5% Output current:within 90mA Ratio metric type (Up to six 350Ω load cells can be connected in parallel.) |
|---|---|
| Signal input range | -0.5~3.0mV/V |
| Zero adjustment range | Automatic adjustment by digital operation -0.2~2.0mV/V |
| Span adjustment range |
Automatic adjustment by digital operation |
| Minimum input sensitivity | 0.15μV/count |
| Accuracy |
|
| A/D converter | Conversion rate…300 times/sec. Conversion resolution…24bit(binary) |
| Minimum indication resolution | 1/10000 |
| Secondary calibration | Equivalent input calibration Minimum indication resolution for secondary calibration:1/1000(ordinary temperature) |
| Setting | |
| Setting method | Settings are made by operating the membrane keys. Also, settings can be made from a host computer through the RS-485 interface. |
|---|---|
| Memory of set value | Calibration value and a part of set value: NOV.RAM (nonvolatile RAM) Other set values: F-RAM (nonvolatile RAM) |
| Protect of set value | Protect can be set by Lock switch and Lock parameter. |
| Setting item |
Upper limit/Lower limit/Near zero/Set point 1/Set point 2/Compensation/Over/Under/Final/Comparison inhibit time/Judging time/Complete output time/Compensation feeding time/Auto free fall compensation regulation/Weighing function 1/Weighing function 2/Tare setting/Tare display/Digital low pass filter/Moving average filter/MD/ZT period/ZT range/Total comparison selection/Total limit (most significant 4 digits)/Total limit (least significant 5 digits)/Count limit/Weighing function 3/Key invalid・Lock/Input selection 1/Input selection 2/Output selection 1/Output selection 2/Error output selection/Reserve output selection/Password/Bag clamp output time/Discharging time/Weighing start time/AZ times/Judging times/Sequence mode 1/Sequence mode 2/Filling enhancement value/Expanded function selection 1/Expanded function selection 2/Balance weight value/Capacity/Min. scale division/DZ regulation value/Display selection 1/Gravitational acceleration/Net over/Gross over/Display selection 2/RS-485 I/F setting/RS-485 Communication type/RS-485 ID/Transmission delay time/Zero calibration/Span calibration/Equivalent calibration/Option display |
| External signal (You can specify whether PNP (Source) type or NPN (Sink) type when order the F701-S.) | |
| Output signals(16points) | SP1/SP2/SP3/Complete/Discharge/Bag clamp /Error selection 1,2/Output selection 1~6/Reserve 1,2 At signal ON, output transistor ON. ※External voltage must be prepared separately by customer. |
|---|---|
| Input signals (16points) |
Operation permission/Weighing start/Stop/Discharge command/Manual discharge/Discharge gate open/Accumulation clear/Input selection 1~6/Code 1,2,4 Contact (relay, switch etc.) or non-contact (transistor, open collector etc.) can be connected. ※External voltage must be prepared separately by customer. |
| Interface | |
| RS-485 communication interface (Select from Modbus-RTU and original format) |
| Display | |
| Display | 18.5mm in character height, Numerical display on LCD(7 digit) Sub display:7.3mm in character height (14 digit) |
|---|---|
| Indicated value | 5 digit sign: negative display at the highest digit |
| Accumulation value | 9 digit ※This can be changed to "Accumulation count (4 digit)", "Final(5 digit)" and "Code(1 digit)". |
| Display frequency | Select from 1, 2, 5, 10, 20 times/sec.(The system speed is 300 times/sec.)) |
| Capacity | 5 digit |
| Min. scale division | Setting allowable in the range of 1~50. |
| Decimal point | Select from 0, 0.0, 0.00, 0.000 |
| Over display | LOAD:A/D converter input over, OFL1:Net Over, OFL2:Capacity +9 scale division, -OFL2:Capacity -over or -20 scale division over, OFL3:Gross Over |
| Center zero | A true zero point or the center of each value is displayed. |
| Status display | CLAMP/SP3/SP2/SP1/HOLD/ COMPL./ZT/ZALM/STAB/TARE/NET/GROSS/NZ/ D.CHG/HI LIM/HI/GO/LO/LO LIM/CZ/LOCK |
| General specification | |
| Power supply voltage | AC100~240V(+10%-15%) (free power source 50/60Hz) |
|---|---|
| Power consumption | 15W max. |
| Inrush current | 2A, 3mSec:AC240V average load condition (cold start at room temperature) |
| Operating conditions | Temperature…Operation -10℃~+40℃ Storage -20℃~+85℃ Humidity…85% or less (non-condensing) |
| External dimensions | 192(W)×96(H)×140(D) mm (Projections excluded) |
| Panel cutout dimensions | 186 +2 -0(W)×92 +1 -0(H)mm ※Installation panel thickness: 2.0~3.2mm |
| Weight | Approx. 2kg |
| Attachment | |
| AC input cord (Nominal rating 125V) 3m | 1 |
|---|---|
| Loadcell connector | 1 |
| Load cell connector rubber | 1 |
| External I/O signal connector | 1 |
| Operation manual | 1 |
| Rubber packing | 1 |
Optional Accessories
| Product | Description |
| CAAC3P-P2 | AC input cord 2m |
|---|---|
| CAAC3P-CEE7/7-P1.5 | AC input cord(voltage resistance:250V)1.5m |
| CA4131 | (6-wired)cable with JRC connector at one end 3m |
| CA4230 | JRC-PRC (6-wired)conversion relay cable 0.3m |
| CA4311 | JRC-PRC (6-wired)conversion relay cable (4-wired to 6-wired)(for 520A use)1m |
| CN3P-2P | 3P-2P converter plug for AC input cord |
| CN10 | Loadcell connector |
| CN52 | FCN series I/O connector (with cover) |
| CN57 | FCN series I/O connector (with diagonal cover) |
| CN82 | RS-485 connector terminal (3P) |
Download
| Product Catalogue | Operation Manuals | External dimentions | Support Tools | Software |
|
|

- Download an operation manual, product appearance diagram, support tool or software after user registration.
- Acrobat Reader software from Adobe Systems is required to view files in PDF format.













