F701-S

Global standard model High performance design Weighing indicator
 

Product Outline

High grade unit that pursues high specifications and functions.

F701-S is a weighing indicator with high specifications and various functions such as super-low-drift high-precision amplifier, fast-sampling, weighing sequence functions that are useful for automatic weighing machines and control I/O.

製品イメージ
 
 

Specifications

Analog
Excitation voltage DC5V±5% Output current:within 90mA Ratio metric type (Up to six 350Ω load cells can be connected in parallel.)
Signal input range -0.5~3.0mV/V
Zero adjustment range Automatic adjustment by digital operation
-0.2~2.0mV/V
Span adjustment range

Automatic adjustment by digital operation
0.3~3.0mV/V

Minimum input sensitivity 0.15μV/count
Accuracy
  • Non-linearity
  • within 0.01%/FS
  •  
  • Zero drift
  • 0.025μV/℃ RTI typ
  •  
  • Gain drift
  • 1ppm/℃ typ 
A/D converter Conversion rate…300 times/sec.
Conversion resolution…24bit(binary)
Minimum indication resolution 1/10000
Secondary calibration Equivalent input calibration Minimum indication resolution for secondary calibration:1/1000(ordinary temperature)
 
Setting
Setting method Settings are made by operating the membrane keys.
Also, settings can be made from a host computer through the RS-485 interface.
Memory of set value Calibration value and a part of set value: NOV.RAM (nonvolatile RAM)
Other set values: F-RAM (nonvolatile RAM)
Protect of set value Protect can be set by Lock switch and Lock parameter.
Setting item

Upper limit/Lower limit/Near zero/Set point 1/Set point 2/Compensation/Over/Under/Final/Comparison inhibit time/Judging time/Complete output time/Compensation feeding time/Auto free fall compensation regulation/Weighing function 1/Weighing function 2/Tare setting/Tare display/Digital low pass filter/Moving average filter/MD/ZT period/ZT range/Total comparison selection/Total limit (most significant 4 digits)/Total limit (least significant 5 digits)/Count limit/Weighing function 3/Key invalid・Lock/Input selection 1/Input selection 2/Output selection 1/Output selection 2/Error output selection/Reserve output selection/Password/Bag clamp output time/Discharging time/Weighing start time/AZ times/Judging times/Sequence mode 1/Sequence mode 2/Filling enhancement value/Expanded function selection 1/Expanded function selection 2/Balance weight value/Capacity/Min. scale division/DZ regulation value/Display selection 1/Gravitational acceleration/Net over/Gross over/Display selection 2/RS-485 I/F setting/RS-485 Communication type/RS-485 ID/Transmission delay time/Zero calibration/Span calibration/Equivalent calibration/Option display

 
External signal (You can specify whether PNP (Source) type or NPN (Sink) type when order the F701-S.)
Output signals(16points) SP1/SP2/SP3/Complete/Discharge/Bag clamp /Error selection 1,2/Output selection 1~6/Reserve 1,2
At signal ON, output transistor ON. 
※External voltage must be prepared separately by customer.
Input signals
(16points)
Operation permission/Weighing start/Stop/Discharge command/Manual discharge/Discharge gate open/Accumulation clear/Input selection 1~6/Code 1,2,4
Contact (relay, switch etc.) or non-contact (transistor, open collector etc.) can be connected.
※External voltage must be prepared separately by customer.
 
Interface
RS-485 communication interface (Select from Modbus-RTU and original format)
 
Display
Display 18.5mm in character height, Numerical display on LCD(7 digit)
Sub display:7.3mm in character height (14 digit)
Indicated value 5 digit sign: negative display at the highest digit
Accumulation value 9 digit ※This can be changed to "Accumulation count (4 digit)", "Final(5 digit)" and "Code(1 digit)".
Display frequency Select from 1, 2, 5, 10, 20 times/sec.(The system speed is 300 times/sec.))
Capacity 5 digit
Min. scale division Setting allowable in the range of 1~50.
Decimal point Select from 0, 0.0, 0.00, 0.000
Over display LOAD:A/D converter input over,
OFL1:Net Over,
OFL2:Capacity +9 scale division,
-OFL2:Capacity -over or -20 scale division over,
OFL3:Gross Over
Center zero A true zero point or the center of each value is displayed.
Status display CLAMP/SP3/SP2/SP1/HOLD/
COMPL./ZT/ZALM/STAB/TARE/NET/GROSS/NZ/
D.CHG/HI LIM/HI/GO/LO/LO LIM/CZ/LOCK
 
General specification
Power supply voltage AC100~240V(+10%-15%) (free power source 50/60Hz)
Power consumption 15W max.
Inrush current 2A, 3mSec:AC240V average load condition
(cold start at room temperature)
Operating conditions Temperature…Operation -10℃~+40℃ Storage -20℃~+85℃
Humidity…85% or less (non-condensing)
External dimensions 192(W)×96(H)×140(D) mm (Projections excluded)
Panel cutout dimensions 186 +2 -0(W)×92 +1 -0(H)mm
※Installation panel thickness: 2.0~3.2mm
Weight Approx. 2kg
 
Attachment
AC input cord (Nominal rating 125V) 3m 1
Loadcell connector 1
Load cell connector rubber 1
External I/O signal connector 1
Operation manual 1
Rubber packing 1
 

 

Optional Accessories

Product Description
CAAC3P-P2 AC input cord 2m
CAAC3P-CEE7/7-P1.5 AC input cord(voltage resistance:250V)1.5m
CA4131 (6-wired)cable with JRC connector at one end 3m
CA4230 JRC-PRC (6-wired)conversion relay cable 0.3m
CA4311 JRC-PRC (6-wired)conversion relay cable (4-wired to 6-wired)(for 520A use)1m
CN3P-2P 3P-2P converter plug for AC input cord
CN10 Loadcell connector
CN52 FCN series I/O connector (with cover)
CN57 FCN series I/O connector (with diagonal cover)
CN82 RS-485 connector terminal (3P)
 
 

Download

Product CatalogueOperation ManualsExternal dimentionsSupport ToolsSoftware
Rev.1.00
F701-S
Rev.1.02(3.77MB)
 
  • Download an operation manual, product appearance diagram, support tool or software after user registration.
  • Acrobat Reader software from Adobe Systems is required to view files in PDF format.