F770

Desktop Type with Built-in Printer Loadcell Indicator
 

Product outline

F770 is a substantial loadcell indicator having a built-in printer equipped with statistical functions.

F770 has multi-hold modes such as Stab, Average, Sample and Peak to suit your application, in addition to Auto Hold for mobile objects ideal for checker scales. Fully equipped with various other functions including the counting function to display the parts quantity and the HI/LO limit comparison function, F770 is a substantial loadcell indicator having a built-in printer equipped with statistical functions.

Desktop Loadcell Indicator F770
 
 

Specifications

ANALOG SECTION
Excitation voltage 10V DC ±5%, Output current; within 180mA, Ratiometric method (Up to 6 loadcells at 350Ω are parallel-connectable.)
Zero adjustment range ±2mV/V
Gain adjustment range 0.5 - 3.0mV/V
Min. input sensitivity 0.5μV / count
Accuracy Non-linearity: within 0.01% FS
Zero drift: within 0.2μV/°C RTI
Gain drift: within 15 ppm/°C
Noise: within 0.3μVp-p RTI (0.1 - 10 Hz)
Analog filter None, digital filter only
A/D converter Speed: 50 times/sec
Resolution: 16 bit (binary)
Min. display resolution 1/10000
 
SETTING SECTION
Setting method Keyboard operation (membrane switch with a key click buzzer)
Setting value storage NOV RAM (Non-volatile RAM)
Setting value protection Setting operation can be locked (LOCK).
Main setting items HI-HI LIM, HI LIM, OK/NG, LO-LIM, LO-LO LIM, NEAR ZERO, TARE, UNIT WEIGHT, INTERVAL BORDER, COMPARISON CONDITIONS, etc.
 
INPUT/OUTPUT SECTION
External input signal ON when shorted to COM terminal by contact (relay, switch) or non contact (transistor, open collector)
Gross / net change, digital zero, subtotal, batch, table, hold, judgment, tare subtraction, feed, total, print, polarity reversal of net weight, selection
External output signal Transistor’s open collector output (Emitter=COM terminal) Output is LO when transistor is ON.
HOLD, HI-HI LIM, OK/NG, LO-LO LIM, WEIGHT ALARM, ERROR, NEAR ZERO, HI LIM, LO LIM, STAB, OPERATING
Interface SIF:2-wire type serial interface
 
DISPLAY SECTION
Weight display unit 7 digits, 18 mm in character height, dedicated fluorescent display tube
Display value 5 digits, Minus sign on most significant digit.
Quantity display 4 digits, Sign; minus display, Unit; pcs
Display frequency Selectable 3, 6, 13, 25 times/sec
Min. scale division 1 to 100
Decimal point Selectable decimal place at 0/0.0/0.00/0.000
Center zero True zero point (0±1/4 scale) or the center of each value is displayed.
Unit display Selectable from t, kg, g, N. lb, none  kg ⇔ lb automatic conversion function selectable (weight) pcs (quantity)
Status display CENTER ZERO, STAB, TARE, NET, GROSS, ZT, ZALM, LOCK, HI LIM, HI, GO, LO, LO LIM, HOLD, NZ
 
PRINTER SECTION
Print system 5 x 7 dot, impact printing
Print speed Approx. 2 lines/sec (approx. 50 pcs)
No. of Print digits 24 digits
 
GENERAL SPECIFICATIONS
Power supply voltage 85 - 110V, 102 - 132V, 170 - 220V, 187 - 242V AC (Please specify when ordering), 50/60 Hz
Power consumption Approx. 20VA
Operating conditions Temperature: Working temperature range -10°C - +40°C
Humidity: 85% RH or less (non-condensing)
External dimensions 263 (W) x 95 (H) x 183 (D) [mm] (protruding parts not included)
Weight Approx. 2.2 kg
 
ACCESSORIES
AC input cord (3 m) 1
Spare fuse (1A) 1
External input / output signal connector 1
Loadcell connector 1
Crimping terminal 5
Ink ribbon cassette 2 (1 pc. installed in the main unit)
Rolled paper 1
Nameplate seal 1
Operation Manual 1
 
 

Optional accessories

Model Description
PP350/10 Rolled paper (10 rolls)
PP350-2P/10 Rolled paper 2-sheet copy (10 pc.)
PR350/10 Ink ribbon (10 pcs)
CAAC2P-B3 AC input cord (3 m)
CAAC3P-CEE7/7-B2 AC input cord (withstand voltage: 250V) (2 m)
CA573Y31 57/14p (6-core) cable (cable end is separated) (3 m)
CA574030 57/14p-PRC (6-core) cable (0.3 m)
CN20 Loadcell connector 57 series (14p)
CN21 57 series 36p connector for external I/O
 
 

Download

Product CatalogueOperation manualExternal dimentionSupport toolsSoftware
F770
Rev.1.14(3.33MB)
 
  • User registration is required to download operation manuals, external dimentions, support tools and software.
  • Acrobat Reader software from Adobe Systems is required to view PDF files.