Product outline
- Can measure up to 20 kN with diameter of 21 mm!
- Capacity 10 kN/ 20 kN
- Also supports high/low temperature environment from -40℃ to 150℃ (HL)
Specifications
| Model | UCC-10KN | UCC-20KN | UCC-10KN (HL) |
UCC-20KN (HL) |
|---|---|---|---|---|
| Rated capacity | 10 kN | 20 kN | 10 kN | 20 kN |
| Rated output | Approx. 1 mV/V | |||
| Safe overload | 120% R.C. | |||
| Zero balance | ±10% R.O. | |||
| Non-linearity | 0.5% or less R.O. | |||
| Hysteresis | 0.5% or less R.O. | |||
| Repeatability | 0.2% or less R.O. | |||
| Compensated temperature range |
0 to +50℃ | -40 to +150℃ | ||
| Safe temperature range |
-10 to +60℃ | -40 to +150℃ | ||
| Temperature effect on zero |
0.5% R.O/10℃ or below | |||
| Temperature effect on span |
0.5% R.O/10℃ or below | |||
| Input resistance | Approx. 350 Ω | |||
| Output resistance | Approx. 350 Ω | |||
| Recommended excitation voltage |
2.5 V | |||
| Maximum excitation voltage |
5 V | |||
| Insulation resistance (DC50V) |
1000 MΩ or more | |||
| Cable | φ2 4-conductor flexible cable (2 m) Cable end: 5 wires |
φ2 4-conductor fluorine resin cable (3 m) Cable end: 5 wires |
||
| Load cell material | Stainless steel | |||
| Deflection at rated | 0.030 mm | 0.045 mm | 0.030 mm | 0.045 mm |
| Natural frequency | 54 kHz | 55 kHz | 54 kHz | 55 kHz |
| Weight | 20 g | |||
| RoHS directives | 2011/65/EU (EU)2015/863 | |||
Example of use, Wiring diagram

External dimension

Download
|
Product catalogue(PDF)
|
⇒Download Page | |
|---|---|---|
|
Operation manual(PDF)
|
||
|
External dimension
|
DXF
(ZIP) |
|
|
PDF
|
||
|
Support tools
|
||
|
Software
|
||